Indoor Water HeaterOutdoor Water HeaterFOR YOUR SAFETY!— Do not store or use gasoline or otherflammable vapors or liquids or othercombustible materia
10Water Supply ConnectionsIMPORTANT: Do notapply heat to the HOT orCOLD water connections. Ifsweat connections are used,sweat tubing to adapterbefore
Installing the water heater:Relief ValveA new pressure relief valve, complyingwith the Standard for Relief Valves andAutomatic Gas Shut-Off Devices fo
12WARNING: Do not attempt to convert this water heater for use with a different type of gas other than the typeshown on the rating plate. Such convers
Installing the water heater:The water heater must be installed with a vent adapter such as 9401RHM or FSAA4 or a UL approvedCategory III Stainless Ste
14Venting Through Closed SpacesIf the vent piping passes through a closed space, a minimumclearance of 8” (20 cm) when installed horizontally, 6” (15
15DVVEFIXEDCLOSEDOPERABLEOPERABLEFIXEDCLOSEDvvBLFCBvvvXBBBAJBIHXvMKvGAThe following information should be used for determining the proper location of
16Installing the water heater:Additional ConsiderationsDo Not install vent terminal under any patio or deck.To help prevent moisture from freezing on
17Vent Horizontal Wall Thimble InstallationAn approved 4 inch (10 cm) VentHorizontal Wall Thimble must be used.The Wall Thimble requires mechanicalsup
18Installing the water heater.Vertical Vent InstallationOnce the vent terminal location has beendetermined, make a hole through the roofand interior c
19Remote Control InstallationOne (1) remote control is provided withthe water heater.The following are considerations fordetermining the location of t
Safety InformationSafety Precautions . . . . . . . 3–6LP Gas Models . . . . . . . . . . . 5Installation InstructionsLocation of Indoor. . . . . . .
20Installing the Main Remote Control.WARNING: Field wiring connections and electrical grounding must comply with localcodes, or in the absence of loca
21Electrical ConnectionPOWER CORD (Indoor water heatersonly):● The electric power supply requirementfor this water heater is 120 VAC/60HZ,2 Amps.● The
22Installing the water heater.Typical Installation of Indoor Water Heater90° Elbow1/4" Per Foot Downward PitchWall ThimbleVent TerminationWith Pr
23Installing the water heater:Typical Installation of Outdoor Water HeaterTo Hot WaterFaucet(s)DischargeLine(To Suitable Drain)ReliefValveUnionDrain V
24For increased energy efficiency, use pipeinsulation. Please install the insulation,according to the illustrations above,making sure to insulate all
Installing the water heater:25A. Outdoor Water Heater Location❑ Outdoor water heaters must be installed outdoors.❑ Protected from freezing temperature
26Lighting the water heater:Before operating this water heater, be sure to read and follow the instructions on the label picturedbelow and all other l
27Time/Temperature Relationship in ScaldsWater Temperature Time To Produce a Serious Burn120°F (49°C) More than 5 minutes125°F (52°C) 11/2 to 2 minute
28Water Temperature Setting…Maximum water temperature occurs whilethe burner is on. To determine the watertemperature, turn on a hot water faucetand p
29Care and cleaning of the water heater:Routine Preventative MaintenanceProperly maintained, your water heaterwill provide years of dependable trouble
Be sure to read and understand the entire Instruction Manual before attempting to install or operatethis water heater. It may save you time and money.
30Venting System Inspection The venting system of an indoor waterheater should be inspected annually toensure all of the vent sections are secureand a
31Draining the Water HeaterFreeze ProtectionWhere the water heater may be exposed tofreezing conditions, even for a shortperiod of time, be sure to dr
32Before You Call For Service…Troubleshooting TipsSave time and money! Review the charts on the following pages first and you may not need to call for
Error Code GuideWhen an error code is displayed:● Close the hot water faucet, turn off the switch on theremote control.● Wait for about 5 minutes befo
SPARK UNITACS-201XA.C. 100V0401ON1234DIP1ONOFF1234SW1 SW2SW3Gas ValveAssemblyHeat ExchangerThermistorHeat ExchangerOutletThermistorBurnerAssembly(with
35Required adjustment for up to 180°F (82°C) water temperature settings WARNING: Refer to scald potential warnings on page 4 beforemaking adjustment.
36IF YOU NEED SERVICE1. Should you have any questions about your new water heater, or if it requiresadjustment, repair, or routine maintenance, it is
LIMITED WARRANTYFor the PALOMA Gas Water Heater Models listed on the front of this manual.GENERALThis Limited Warranty is only available to the origin
l) Damages, malfunctions, or failures resulting from the use of any attachment, including any energy saving device,not authorized by Paloma.m) Units i
SPECIFICATIONS (Approx.)Model PH-28CIFSN Indoor (Natural Gas) PH-28COFN Outdoor (Natural Gas)PH-28CIFSP Indoor (L. P. Gas)
Time/Temperature Relationship in ScaldsWater Temperature Time To Produce a Serious Burn120°F (49°C) More than 5 minutes125°F (52°C) 11/2 to 2 minutes1
Paloma Industries, Inc.2151 Eastman AvenueOxnard, CA 93030PRINTED IN JAPAN31-52751
5Both LP and natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odora
6Have the installer show you the location of the gas shut-off valve and how to shut it off ifnecessary. Turn off the manual shut-off valve if the wate
Installing the (INDOOR) water heater :This water heater must be installed in accordance with these instructions, local codes, utility companyrequireme
8Installing the (OUTDOOR) water heater:This water heater must be installed in accordance with these instructions, local codes, utility companyrequirem
Installing the water heater:Proper operation of the water heater requires air for combustion and ventilation. Provisions forcombustion and ventilation